3 shorten suspension cable – VEGA VEGAWELL 72 4 … 20 mA User Manual

Page 24

Advertising
background image

l

N

o voltage supply

à Check cables for breaks; repair if necessary

l

supply voltage too low or load resistance too high

à Check, adapt if necessary

I

n Ex applications, the regulations for the wiring of intrinsically

safe circuits must be observed.

D

epending on the failure reason and measures taken, the

steps described in chapter "Set up" must be carried out again,
if necessary.

7

.3 Shorten suspension cable

T

he suspension cable can be shortened individually. For the

version with plastic or stainless steel housing proceed as
follows:

1

U

nscrew the housing cover

2

L

oosen the screw terminals and remove the wire ends of

the suspension cable out of the screw terminals

3

H

old the hexagon on the screwed socket with SW 46 and

loosen with seal screw SW 22

Caution:
S

eal screw is secured with Loctide pink, mote breakaway

torque!

Reaction after fault rec-
tification

24

VEGAWELL

72 • 4 … 20

mA

7 M

aintenance and fault rectification

27501

-EN

-080806

Advertising