Thermal change zero signal and output span with absolute pressure measuring range 0.1 bar,
reference temperature 20 °C (68 °F):

-

In the compensated temperature range
0 … +100 °C (+32 … +212 °F)

< (0.1 % + 0.1 % x TD)

-

Outside the compensated temperature
range

< (0.15 % + 0.15 % x TD)

Applies also to instruments with analogue 4 … 20 mA current output and refers to the set span.

Thermal change, current output

< 0.15 % at -40 … +80 °C (-40 … +176 °F)

Long-term stability (similar to DIN 16086, DINV 19259-1 and IEC 60770-1)

Applies to digital interfaces (HART, Profibus PA, Foundation Fieldbus) as well as to analogue
current output 4 … 20 mA. Specifications refer to the set span. Turn down (TD) = nominal
measuring range/set span.

Long-term drift of the zero signal

< (0.1 % x TD)/year

Ambient conditions

Ambient, storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions

The specifications to the pressure stage and the product temperature are used as an overview.
The specifications of the type label are applicable.

Pressure stage, process fitting

-

Thread 316L

PN

60

-

Thread Aluminium

PN

25

-

Thread PVDF

PN

10

-

Hygienic fittings 316L

PN

6, PN 10, PN 25, PN 40

-

Flange 316L

PN

16, PN 40,150 lbs, 300 lbs, 600 lbs

-

Flange with extension 316L

without PN specification, PN 16, PN 40 or 150 lbs,
300 lbs, 600 lbs

-

Flange PVDF

PN

16

Product temperature standard version, depending on the meas. cell seal

12)

-

FKM (VP2/A)

-20 … +120 °C (-4 … +248 °F)

-

EPDM (A+P 75.5/KW75F)

-40 … +120 °C (-40 … +248 °F), 1 h: 140 °C/284 °F
cleaning temperature

-

FFKM (Kalrez 6375)

-10 … +120 °C (+14 … +248 °F)

-

FFKM (Chemraz 535)

-30 … +120 °C (-22 … +248 °F)

Product temperature version with extended temperature range, depending on the meas. cell seal
as well as order specification

-

FKM (VP2/A)

-20 … +150 °C (-4 … +302 °F)

-

EPDM (A+P 75.5/KW75F)

-40 … +150 °C (-40 … +302 °F)

12)

With process fitting PVDF, max. 100 °C (212 °F).

58

VEGABAR

64 • Foundation Fieldbus

10 Supplement

28259

-EN

-081209

Advertising