2 adjustment elements – VEGA VEGAVIB 55 - two-wire User Manual

Page 19

Advertising
background image

6.2 Adjustment elements

4

1

2

3

Fig. 10: Electronics module - Two-wire output

1

DIL switch for mode adjustment

2

Ground terminal

3

Screwed terminals

4

Control lamp

With the mode adjustment (min./max.) you can determine the

output current.
When using a signal conditioning instrument, always set the

mode switch to max. mode.
In this case, you select the requested mode according to the

"Function chart" (max. - max. detection or overfill protection,

min. - min.detection or dry run detection) on the signal

conditioning instrument.
When used on a control system, the following values apply:

l

Mode min.

- Vibrating element uncovered - 16 mA ±1 mA

-

Vibrating element covered - 8 mA ±1 mA

l

Mode max.

- Vibrating element uncovered - 8 mA ±1 mA

-

Vibrating element covered - 16 mA ±1 mA

Control lamp for indication of the switching condition.

l

green = 8 mA

l

red = 16 mA

l

red (flashing) = Failure (<2.3 mA)

Mode adjustment (1)

Signal lamp (4)

VEGAVIB 55 - - two-wire

19

Setup

29304

-EN

-070109