Mode on the
signal condi-
tioning in-
strument
Level
Signal cur-
rent - Sen-
sor
Signal lamp
- sensor
Signal
lamp - sig-
nal condi-
tioning in-
strument
Mode A
Overfill pro-
tection
approx. 8 mA
Green
Mode A
Overfill pro-
tection
approx.
16 mA
red
Mode B
Dry run pro-
tection
approx.
16 mA
red
Mode B
Dry run pro-
tection
approx. 8 mA
Green
Failure mes-
sage
(mode A/B)
any
<2.3 mA
flashes red