Process pressure
-1 … 6 bar/-100 … 600 kPa (-14.5 … 87 psi)
Process temperature
-50 … +100 °C (-58 … +212 °F)
Density
>0.08 g/cm³ (0.003 lbs/in³)
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Cable entry/plug
2)
- Single chamber housing
l
1x cable entry M20x1.5 (cable-ø 5 … 9 mm),
1x blind stopper M20x1.5
or:
l
1x closing cap ½ NPT, 1x blind plug ½ NPT
or:
l
1x plug (depending on the version), 1x blind
plug M20x1.5
Spring-loaded terminals
for wire cross-section up to 1.5 mm²
(0.0023 in²)
Adjustment elements
Mode switch
- min.
Min. detection or dry run protection
- max.
Max. detection or overfill protection
Voltage supply
Supply voltage
10 … 36 V DC (via the signal conditioning
instrument)
Electrical protective measures
Protection
IP 66/IP 67
Overvoltage category
III
Protection class
II
2)
Depending on the version M12x1, according to DIN 43650, Harting, Am-
phenol-Tuchel, 7/8" FF.