VEGA VEGAPULS 62 (≥ 2.0.0 - ≤ 3.8) Foundation Fieldbus User Manual
Page 57
Step response or adjustment time
5)
< 1
s (dependent on the parameter settings)
Max. level change
Adjustable up to 1 m/min. (dependent on the
parameter adjustment)
Max. emitted HF power of the antenna system
-
Pulse peak power
< 2
mW
-
Pulse duration
< 2
ns
-
Average power
< 5 µW
-
Average power with 1 m distance
< 200
nW/cm
2
Max. emitted HF power of the antenna system - Version with increased sensitivity
-
Pulse peak power
< 10
mW
-
Pulse duration
< 2
ns
-
Average power
< 25 µW
-
Average power with 1 m distance
< 1 µW/
cm
2
Measuring accuracy
Resolution, general
< 1
mm (0.039 in)
Deviation
6)
see diagrams
0,5 m (1.6 ft)
30 m (98.43 ft)
10 mm (0.394 in)
3 mm (0.116 in)
- 3 mm (- 0.116 in)
- 10 mm (- 0.394 in)
0
Fig. 37: Deviation VEGAPULS 62 with horn antenna
5)
Time to output the correct level (with max. 10 % deviation) after a sudden
level change.
6)
Incl. non-linearity, hysteresis and non-repeatability.
VEGAPULS
62 • Foundation Fieldbus
57
10 Supplement
28450
-
EN
-090305