VEGA VEGAPULS 62 (≥ 2.0.0 - ≤ 3.8) Foundation Fieldbus User Manual

Page 60

Advertising
background image

Vessel pressure - horn antenna

-1 … 40 bar/-100 … 4000 kPa (-14.5 … 580 psi)

Vessel pressure - parabolic antenna

-1 … 6 bar/-100 … 6000 kPa (-14.5 … 870 psi)

Vessel pressure relating to the flange nom-
inal stage

see supplementary instructions manual "Flanges
according to DIN-EN-ASME-JIS
"

Vibration resistance

8)

-

Horn antenna

mechanical vibrations with 4 g and 5 … 100 Hz

-

Parabolic antenna

mechanical vibrations with 1 g and 5 … 100 Hz

Data on rinsing air connection

Pressure

< 6

bar (87.02 psi)

Air quantity see diagram

0,1

0,0

1,0

2,0

3,0

4,0

5,0

6,0

0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2,0

(bar)

(m

3

/h)

Fig. 41: Air quantity diagram

Thread

G⅛ A

Catch

-

with non-Ex

Dust protection cover of PE

-

with Ex

Threaded plug of 316Ti

Reflux valve - unmounted (as option with non-Ex version, included in the scope of delivery with Ex
version)

-

Material

316Ti

-

Seal

FKM (Viton), FFKM (Kalrez 6375)

-

for tube diameter

6 mm

-

opening pressure

0.5 bar (7.252 psi)

-

Nominal pressure stage

PN

250

8)

Tested according to the regulations of German Lloyd, GL directive 2.

60

VEGAPULS

62 • Foundation Fieldbus

10 Supplement

28450

-EN

-090305