VEGA VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) Foundation Fieldbus User Manual

Page 53

Advertising
background image

-

TFM-PTFE hygienically encapsulated,
process seal FKM (Viton)

-25 … +130 °C (-13 … +266 °F)

-

TFM-PTFE hygienically encapsulated,
process seal EPDM

-40 … +130 °C (-40 … +266 °F)

Vibration resistance

mechanical vibrations with 4 g and 5 … 100 Hz

10)

Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar

Cable entry/plug

11)

-

Single chamber housing

l

1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5

or:

l

1 x closing cap M20 x 1.5; 1 x blind stopper
M

20 x 1.5

or:

l

1 x closing cap ½ NPT, 1 x blind plug ½ NPT

or:

l

1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5

-

Double chamber housing

l

1 x cable entry M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5; 1 x blind stopper
M

16 x 1.5 or optionally available with 1 x plug

M

12 x 1 for external indicating and adjustment

unit

or:

l

1 x closing cap ½ NPT, 1 x blind stopper
½ NPT

, 1 x blind stopper M16 x 1.5 or

optionally 1 x plug M12 x 1 for external
indicating and adjustment unit

or:

l

1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5; 1 x blind stopper M16 x 1.5
or optionally available with 1 x plug M12 x 1 for
external indicating and adjustment unit

Spring-loaded terminals for wire cross-sec-
tion

< 2

.5 mm² (AWG 14)

Electromechanical data - version IP 66/IP 68 (1 bar)

Cable entry

-

Single chamber housing

1 x IP 68 cable gland M20 x 1.5; 1 x blind stopper
M

20 x 1.5

-

Double chamber housing

1 x IP 68 cable gland M20 x 1.5; 1 x blind stopper
M

20 x 1.5; 1 x blind stopper M16 x 1.5

10)

Tested according to the guidelines of German Lloyd, GL directive 2.

11)

Depending on the version M12 x 1, according to DIN 43650, Harting, 7/
8" FF.

VEGAPULS

63 • Foundation Fieldbus

53

10 Annex

28451

-

EN

-120530

Advertising