4 mounting, 1 general instructions, 2 carrier – VEGA VEGALOG 571 CPU and carrier User Manual

Page 10

Advertising
background image

4 Mounting

4.1 General instructions

The module cards of VEGALOG 571 can only be mounted into

the 19" carrier BGT LOG 571. It is provided with a special bus

board for data transmission between CPU and the individual

peripheral cards (LOGBUS). The carrier is designed for

mounting into a switching cabinet or 19" housing.
The plug position for the individual cards is individually

selectable, the system saves the card positions when switch-

ing on.

Note:

The plug positions must not be changed after the parameter

adjustment because measurement loops that have already

been set up would otherwise have to be reconfigured.

4.2 Carrier

By means of the plug connectors on the bus board, a fixed

pattern is created for the use of the modules. This ensures that

each module card is plugged into the multipoint connector and

also into its LOGBUS socket.

l

Number of subunits (TE)

-

84 TE, thereof one 4 TE blind cover on module 1

l

Width of the module cards

-

5 TE for CPU and peripheral cards

-

10 TE for VEGASTAB 593

l

Number of module cards in the BGT LOG 571

-

max. 16 pcs. (e.g. 1x VEGASTAB 693, 1x CPU and

13x peripheral cards)

A VEGALOG 571 in the maximum configuration consists of

two completely equipped carriers which are connected to each

other via a pluggable bus cable (see "Chapter Electrical

connection"). Because the bus cable may not be lengthened,

the two carriers must be mounted directly above one another.

Note:

In the following cases, it is recommended to mount a 19"

ventilator to avoid a temperature increase in VEGALOG.

l

If more than one carrier is placed above the other

l

If air cannot circulate in the area of the carrier

10

VEGALOG 571 - CPU and carrier

Mounting