VEGA VEGAFLEX 67 (-200…+400°C) Profibus PA User Manual
Page 50
Advertising
L
0
-10 mm (-0.394
")
10 mm (0.394
")
0,1 m (3.937
"
)
0,15 m
(1.968
")
1
1
Fig. 24: Deviation VEGAFLEX 67 in coax version
1
Dead zone - no measurement possible in this area
L
Probe length
Influence of the ambient temperature to the sensor electronics
Temperature drift
0.03 %/10 K relating to the max. measuring range
or max. 0.3 %
Temperature drift - Digital output
3 mm/10 K relating to the max. measuring range or
max. 10 mm
Ambient conditions
Ambient, storage and transport temperature
-
40 … +80 °C (-40 … +176 °F)
Process conditions
Process pressure
-
1 … +400 bar/-100 … +40000 kPa (-
-
14.5 … +5800 psig), depending on the process
fitting