VEGA VEGAFLEX 67 (-200…+400°C) Profibus PA User Manual

Page 9

Advertising
background image

It is designed for industrial use in all areas of process technology and
can be used in liquids.

High frequency microwave impulses are guided along a steel cable or
rod or a rod inside a steel tube. When reaching the product surface, a
part of the microwave impulses is reflected. The other part passes the
upper product and is reflected a second time by the interface. The
running times to the two product layers are processed by the
instrument.

Upper medium (L2)

l

The upper medium must not be conductive

l

The dielectric figure of the upper medium must be known (input
required). Min. dielectric figure: rod version 1.7; coax version 1.4.
You can find a list with the dielectric figures on our home page:
www.vega.com

l

The composition of the upper medium must be stable, no varying
products or mixtures

l

The upper medium must be homogeneous, no stratifications within
the medium

l

Min. thickness of the upper medium 100 mm

l

Clear separation from the lower medium, no emulsion phase, no
mull layer

l

If possible, no foam on the surface

Lower medium (L1)

l

The dielectric figure must be 10 higher than the dielectric figure of
the upper medium, preferably electrically conductive. Example:
upper medium dielectric figure 2, lower medium at least dielectric
figure 12

Functional principle

Prerequisites for inter-
face measurement

VEGAFLEX

67 • Profibus PA

9

3 Product description

32313

-

EN

-120329

Advertising