5 setup, 1 setup preparations, 2 setup steps – VEGA PROTRAC series 30 Electronics module User Manual

Page 18

Advertising
background image

18

5 Setup

Electronics module • PROTRAC series 30

40104-EN-130916

5 Setup

5.1 Setup preparations

If you ordered the electronics module by stating the sensor serial

number, it is ready for the setup procedure immediately after installa-

tion and connection to power supply.

If you ordered the electronics module without stating the sensor

serial number or you are using a suitable electronics module from

stock, you first have to load the sensor data after installation.
Under the address www.vega.com go to item "Serial number search".

The order data of the sensor is displayed after you enter the sensor

serial number.
Below the order data you will find "Sensor data for Service-DTM" as

an XML file. This file contains all sensor-specific parameters as well

as the factory settings.
Load this file with "Save target as" on your PC. Start PACTware and

under "Instrument data" go to the menu item "Additional functions",

then to "Electronics exchange". Transfer the XML file to the sensor.

5.2 Setup steps

If the instrument is used in the same application after the electronics

exchange, the previous parameter settings of the instrument must be

restored. To do this, you can use the import function of the adjustment

software PACTware with the device DTMs or the copy function of the

indicating and adjustment module.
If no copy of the parameter settings is available, you have to carry out

a fresh setup. See the operating instructions of the sensor.