9

4 Mounting

Electronics module • PROTRAC series 30

40104-EN-130916

Fig. 2: Profibus PA - Remove the cover foil above the address selection switches

To avoid the accidental use of a non-permissible electronics module,

the terminal blocks are coded.
On the opposite side, you must code the electronics module accord-

ing to your sensor.
In the following illustration there is an example of a sensor coded

without Ex approval (coding pin in terminal 4).
In terminal 2 there is already a coding pin. This coding prevents the

two terminal blocks from being exchanged.

Fig. 3: Inserted coding pin
A Coding pin (e.g. for a sensor without approval)

You must code your sensor according to the new electronics module

of your sensor.

Terminal 3 - Sensors with Ex approval intrinsically safe (ia)