VEGA VEGABAR 52 - climate compensated User Manual

Page 47

Advertising
background image

A

djustment range of the zero/span adjustment relating to the nominal measuring range:

-

zero

-20 … +95 %

-

S

pan

-120 … +120 %

7)

-

D

ifference between zero and span

max. 120 % of the nominal range

R

ecommended max. turn down

5 : 1 (

no limitation)

Nominal measuring ranges and overload capability in bar/kPa

Nominal range

Overload, max. pressure Overload, min. pressure

G

auge pressure

0 … 0.2

bar/0 … 20 kPa

35

bar/3500 kPa

-1

bar/-100 kPa

0 … 0.4

bar/0 … 40 kPa

50

bar/5000 kPa

-1

bar/-100 kPa

0 … 1

bar/0 … 100 kPa

50

bar/5000 kPa

-1

bar/-100 kPa

0 … 2.5

bar/0 … 250 kPa

65

bar/6500 kPa

-1

bar/-100 kPa

0 … 5

bar/0 … 500 kPa

65

bar/6500 kPa

-1

bar/-100 kPa

0 … 10

bar/0 … 1000 kPa

90

bar/9000 kPa

-1

bar/-100 kPa

0 … 25

bar/0 … 2500 kPa

130

bar/13000 kPa

-1

bar/-100 kPa

0 … 60

bar/0 … 6000 kPa

200

bar/20000 kPa

-1

bar/-100 kPa

-1 … 0

bar/-100 … 0 kPa

35

bar/3500 kPa

-1

bar/-100 kPa

-1 … 1.5

bar/-100 … 150 kPa

50

bar/5000 kPa

-1

bar/-100 kPa

-1 … 5

bar/-100 … 500 kPa

65

bar/6500 kPa

-1

bar/-100 kPa

-1 … 10

bar/-100 … 1000 kPa

90

bar/9000 kPa

-1

bar/-100 kPa

-1 … 25

bar/-100 … 2500 kPa

130

bar/13000 kPa

-1

bar/-100 kPa

-1 … 60

bar/-100 … 6000 kPa

200

bar/20000 kPa

-1

bar/-100 kPa

-0.1 … 0.1

bar/-10 … 10 kPa

35

bar/3500 kPa

-1

bar/-100 kPa

-0.2 … 0.2

bar/-20 … 20 kPa

35

bar/3500 kPa

-1

bar/-100 kPa

-0.5 … 0.5

bar/-50 … 50 kPa

50

bar/5000 kPa

-1

bar/-100 kPa

Nominal measuring ranges and overload capability in psig

Nominal range

Overload, max. pressure Overload, min. pressure

G

auge pressure

0 … 3

psig

500

psig

-15

psig

0 … 6

psig

700

psig

-15

psig

0 … 15

psig

700

psig

-15

psig

0 … 35

psig

950

psig

-15

psig

0 … 70

psig

950

psig

-15

psig

0 … 150

psig

1300

psig

-15

psig

0 … 350

psig

1900

psig

-15

psig

0 … 900

psig

2900

psig

-15

psig

-15 … 0

psig

500

psig

-15

psig

7)

V

alues less than -1 bar cannot be set.

VEGABAR

52 • 4 … 20

mA/HART - climate compensated

47

10 S

upplement

35075

-

EN

-081209