VEGA VEGABAR 52 - climate compensated User Manual

Page 49

Advertising
background image

Nominal measuring range in
bar/kPa

Nominal
measuring
range in psig

Average temperature coeffi-
cient of the zero signal9)

Average temperature coeffi-
cient of the zero signal10)

0 … 10

bar/0 … 1000 kPa

0 … 150

psig < (0.02 + 0.03 x TD)%/10K

< (0.04 + 0.06

x TD)%/10K

0 … 25

bar/0 … 2500 kPa

0 … 350

psig < (0.02 + 0.03 x TD)%/10K

< (0.04 + 0.06

x TD)%/10K

0 … 60

bar/0 … 6000 kPa

0 … 900

psig < (0.02 + 0.03 x TD)%/10K

< (0.04 + 0.06

x TD)%/10K

-1 … 0

bar/-100 … 0 kPa

-15 … 0

psig

< (0.02 + 0.03

x TD)%/10K

< (0.04 + 0.06

x TD)%/10K

-1 … 1.5

bar/-100 … 150 kPa -15 … 25 psig < (0.02 + 0.03 x TD)%/10K

< (0.04 + 0.06

x TD)%/10K

-1 … 5

bar/-100 … 500 kPa

-15 … 70

psig < (0.02 + 0.03 x TD)%/10K

< (0.04 + 0.06

x TD)%/10K

-1 … 10

bar/-100 … 1000 kPa -15 … 150 psig < (0.02 + 0.03 x TD)%/10K

< (0.04 + 0.06

x TD)%/10K

-1 … 25

bar/-100 … 2500 kPa -15 … 350 psig < (0.02 + 0.03 x TD)%/10K

< (0.04 + 0.06

x TD)%/10K

-1 … 60

bar/-100 … 6000 kPa -15 … 900 psig < (0.02 + 0.03 x TD)%/10K

< (0.04 + 0.06

x TD)%/10K

-0.1 … 0.1

bar/-10 … 10 kPa

-1.5 … 1.5

psig < (0.05 + 0.05 x TD)%/10K

< (0.05 + 0.1

x TD)%/10K

-0.2 … 0.2

bar/-20 … 20 kPa

-3 … 3

psig

< (0.05 + 0.05

x TD)%/10K

< (0.05 + 0.1

x TD)%/10K

-0.5 … 0.5

bar/-50 … 50 kPa

-7 … 7

psig

< (0.05 + 0.05

x TD)%/10K

< (0.02 + 0.1

x TD)%/10K

Thermal change of the current output

A

pplies also to the analogue 4 … 20 mA current output and refers to the set span.

T

hermal change, current output

<

0.15 %

at -40 … +80 °C (-40 … +176 °F)

Long-term stability (similar to DIN 16086, DINV 19259-1 and IEC 60770-1)

A

pplies to digital HART interface as well as to analogue current output 4 … 20 mA. Specifications

refer to the set span. Turn down (TD) is the relation nominal measuring range/set span.

Nominal measuring range in bar/kPa

Nominal measuring
range in psig

Long-term drift of the zero signal

0 … 0.2

bar/0 … 20 kPa

0 … 3

psig

< (1 %

x TD)/year

0 … 0.4

bar/0 … 40 kPa

0 … 6

psig

< (1 %

x TD)/year

0 … 1

bar/0 … 100 kPa

0 … 15

psig

< (0.25 %

x TD)/year

0 … 2.5

bar/0 … 250 kPa

0 … 35

psig

< (0.25 %

x TD)/year

0 … 5

bar/0 … 500 kPa

0 … 70

psig

< (0.1 %

x TD)/year

0 … 10

bar/0 … 1000 kPa

0 … 150

psig

< (0.1 %

x TD)/year

0 … 25

bar/0 … 2500 kPa

0 … 350

psig

< (0.1 %

x TD)/year

0 … 60

bar/0 … 6000 kPa

0 … 900

psig

< (0.1 %

x TD)/year

-1 … 0

bar/-100 … 0 kPa

-15 … 0

psig

< (0.25 %

x TD)/year

-1 … 1.5

bar/-100 … 150 kPa

-15 … 25

psig

< (0.25 %

x TD)/year

-1 … 5

bar/-100 … 500 kPa

-15 … 70

psig

< (0.1 %

x TD)/year

-1 … 10

bar/-100 … 1000 kPa

-15 … 150

psig

< (0.1 %

x TD)/year

-1 … 25

bar/-100 … 2500 kPa

-15 … 350

psig

< (0.1 %

x TD)/year

-1 … 60

bar/-100 … 6000 kPa

-15 … 900

psig

< (0.1 %

x TD)/year

VEGABAR

52 • 4 … 20

mA/HART - climate compensated

49

10 S

upplement

35075

-

EN

-081209

Advertising