3 Product description

VEGAPULS 67 • HART - integrated accumulator

40795-EN-121011

The scope of delivery encompasses:

Radar sensor with integrated accumulator

Battery charger

Documentation

– this operating instructions manual

– Test certificate measuring accuracy (optional)

– Operating instructions manual "Indicating and adjustment

module" (optional)

– Ex-specific "Safety instructions" (with Ex versions)

– if necessary, further certificates

3.2 Principle of operation

The VEGAPULS 67 is a radar sensor for continuous level measure-

ment of bulk solids under simple process conditions. It is suitable for

smaller silos and vessels.
The instrument is also suitable for applications in liquids.

The antenna of the radar sensor emits short radar pulses with a

duration of approx. 1 ns. These pulses are reflected by the product

and received by the antenna as echoes. The transit time of the radar

pulses from emission to reception is proportional to the distance and

hence to the level. The determined level is converted into an appropri-

ate output signal and outputted as measured value.

The instrument is powered via an integrated accumulator. This allows

operation of the instrument independently of the mains or a control

system. To achieve a longer battery lifetime, the instrument is preset

to HART multidrop. This puts a load of only 4 mA current on the ac-

cumulator.

3.3 Packaging, transport and storage

Your instrument was protected by packaging during transport. Its

capacity to handle normal loads during transport is assured by a test

according to DIN EN 24180.
The packaging of standard instruments consists of environment-

friendly, recyclable cardboard. For special versions, PE foam or PE

foil is also used. Dispose of the packaging material via specialised

recycling companies.

Transport must be carried out under consideration of the notes on the

transport packaging. Nonobservance of these instructions can cause

damage to the device.

The delivery must be checked for completeness and possible transit

damage immediately at receipt. Ascertained transit damage or con-

cealed defects must be appropriately dealt with.

Up to the time of installation, the packages must be left closed and

stored according to the orientation and storage markings on the

outside.