VEGA VEGAPULS 67 (≥ 2.0.0 - ≥ 4.0.0) HART - integrated accumulator User Manual
Page 61
61
11 Supplement
VEGAPULS 67 • HART - integrated accumulator
40795-EN-121011
Ʋ Average spectral transmission power
density
-14 dBm/MHz EIRP
Ʋ Max. spectral transmission power
density
+43 dBm/50 MHz EIRP
Ʋ Max. power density in a distance of
1 m
< 1 µW/cm²
Ambient conditions
Ambient, storage and transport tempera-
ture
-40 … +80 °C (-40 … +176 °F)
Process conditions
Process temperature (measured on the
process fitting)
-40 … +80 °C (-40 … +176 °F)
Vessel pressure
-1 … 2 bar (-100 … 200 kPa/-14.5 … 29.0 psig)
Vessel pressure - version with adapter
flange from DN 150 PP
-1 … 1 bar (-100 … 100 kPa/-14.5 … 14.5 psig)
Vibration resistance
4)
Ʋ Plastic horn antenna with compres-
sion or adapter flange
mechanical vibrations up to 2 g in the frequency range
5 … 200 Hz
Ʋ Plastic horn antenna with mounting
strap
mechanical vibrations up to 1 g in the frequency range
5 … 200 Hz
Indicating and adjustment module
Voltage supply and data transmission
through the sensor
Indication
LC display in dot matrix
Measured value indication
Ʋ Number of digits
5
Ʋ Size of digits
W x H = 7 x 13 mm
Adjustment elements
4 keys
Protection rating
Ʋ unassembled
IP 20
Ʋ mounted into the sensor without cover IP 40
Materials
Ʋ Housing
ABS
Ʋ Inspection window
Polyester foil
Indicating and adjustment elements
Indicating elements
Ʋ Green LED in the supply room
Indication of the charging process
Ʋ Yellow LED in the supply room
Indication of the charging condition
Adjustment elements
Ʋ Rotary switch in the supply room
Selection of the mode
Ʋ Button outside on the housing
Switching on and off
4)
Tested according to the guidelines of German Lloyd, GL directive 2.