4 Mounting

VEGAPULS 67 • HART - integrated accumulator

40795-EN-121011

Fig. 5: Flange mounting of the radar sensor

4.3 Mounting strap

The mounting strap enables simple mounting on the vessel wall or

silo top. It is suitable for wall, ceiling or boom mounting. Especially in

open vessels this is a very easy and effective way to align the sensor

to the bulk solid surface.

Fig. 6: Radar sensor with mounting strap

The strap is supplied unassembled and must be screwed to the

sensor before setup with three hexagon screws M5 x 10 and spring

washers. Max. torque, see chapter "Technical data". Required tools:

Allen wrench size 4.
There are two ways to screw the strap onto the sensor. Depending

on the selected version, the sensors can be swivelled in the strap as

follows: