Quick start

VEGAPULS 67 • HART - integrated accumulator

40795-EN-121011

Quick start

The quick start enables a quick setup with many applications. You

can find further information in the respective chapters of the operating

instructions manual.
1. Distance from the vessel wall > 200 mm

200 mm

(7.87")

Fig. 1: Distance of the antenna to the vessel wall/socket configuration

2. Keep the socket short, round off the socket end
For further information see chapter "Mounting".
1. Insert the battery charger into the socket of the power supply

compartment and load the integrated accumulator before setting

up the instrument.

2. Switch on the instrument by means of the button outside on the

housing.

1

Fig. 2: Switch on/off button outside on the housing
1 On/Off button

For further information see chapter "Connecting to power supply".
1. Go via the indicating and adjustment module to the menu "Setup".

2. Select in the menu item "Medium" the medium of your applica-

tion, for example "Gravel/Pebble".

3. Select in the menu item "Application" the vessel, the application

and the vessel form, for example, silo.

Mounting

Connect electrically

Set parameters