VEGA VEGAFLEX 83 Modbus and Levelmaster protocol PFA insulated User Manual

Page 11

Advertising
background image

11

3 Product description

VEGAFLEX 83 • Modbus and Levelmaster protocol

41838-EN-130314

2

1

Fig. 5: Position of Modbus and sensor electronics
1 Modbus electronics

2 Sensor electronics

This operating instructions manual applies to the following instrument

versions:

Hardware from 1.0.0

Software from 1.0.0

Only for instrument versions without SIL qualification

The respective electronics version can be determined via the product

code on the type label as well as on the electronics.

Standard electronics: Type FX80HK.-

The scope of delivery encompasses:

Sensor

Documentation

– this operating instructions manual

– Test certificate measuring accuracy (optional)

– Operating instructions manual "Display and adjustment mod-

ule" (optional)

– Supplementary instructions "GSM/GPRS radio module"

(optional)

– Supplementary instructions manual "Heating for display and

adjustment module" (optional)

– Supplementary instructions manual "Plug connector for con-

tinuously measuring sensors" (optional)

– Ex-specific "Safety instructions" (with Ex versions)

– if necessary, further certificates

3.2 Principle of operation

The VEGAFLEX 83 is a level sensor with coated cable or rod probe

for continuous level or interface measurement, particularly suitable for

applications in the chemical industry.

High frequency microwave pulses are guided along a steel cable or

a rod. Upon reaching the product surface, the microwave pulses are

reflected. The running time is evaluated by the instrument and output-

ted as level.