VEGA VEGAFLEX 83 Modbus and Levelmaster protocol PFA insulated User Manual

Page 39

Advertising
background image

39

6 Set up with the display and adjustment module

VEGAFLEX 83 • Modbus and Levelmaster protocol

41838-EN-130314

In this menu item, you define the indication of the measured value

on the display. You can display two different measured values. In this

menu item, you define measured value 2.

The default setting for the displayed value 2 is the electronics tem-

perature.

The optionally integrated background lighting can be adjusted via the

adjustment menu. The function depends on the height of the supply

voltage, see "Technical data".

The lighting is switched off in the delivery status.

In this menu item, the device status is displayed.

The respective min. and max. measured value is saved in the sen-

sor. The two values are displayed in the menu item "Peak values,

distance".
If you have selected interface measurement under the menu item

"Setup - Application", then the peak values of the interface meas-

urement are displayed in addition to the peak values of the level

measurement.

In another window you can carry out a reset of the two peak values

separately.

The respective min. and max. measured values are saved in the

sensor. The two values are displayed in the menu item "Peak values,

measurement certainty".
The measurement can be influenced by the process conditions. In

this menu item, the measurement certainty of the level measurement

Display - Displayed value

2

Display - Backlight

Diagnostics - Device

status

Diagnostics - Peak values

Distance

Diagnostics - Peak values

Measurement certainty

Advertising