7 supplementary electronics – VEGA VEGAFLEX 86 4 … 20 mA_HART two-wire Rod and cable probe With SIL qualification User Manual

Page 32

Advertising
background image

32

5 Connecting to power supply

VEGAFLEX 86 • 4 … 20 mA/HART two-wire

44234-EN-130823

Contact pin

Colour connection ca-

ble in the sensor

Terminal, electronics

module

Pin 4

Black

8

5.6 Wiring plan - version IP 66/IP 68, 1 bar

1

2

Fig. 25: Wire assignment fix-connected connection cable
1 brown (+) and blue (-) to power supply or to the processing system

2 Shielding

5.7 Supplementary electronics

You can use the supplementary electronics - second current output to

provided a second measured value.
Both current outputs are passive and need a power supply.

The second current output (II) cannot be used in safety-instrumented

systems according to SIL.

1

2

+

( )

(-)

I

4...20mA

I I

4...20mA

7

8

+

( )

(-)

3

1

2

Fig. 26: Connection compartment double chamber housing, supplementary

electronics - second current output
1 First current output (I) - Voltage supply and signal output (HART)

2 Second current output (II) - Voltage supply and signal output (without HART)

3 Ground terminal for connection of the cable screen

The radio module PLICSMOBILE is an external GSM/GPRS radio

unit for transmission of measured values and for remote parameter

adjustment.

Wire assignment, con-

nection cable

Supplementary electron-

ics - Second current

output

Supplementary elec-

tronics - Radio module

PLICSMOBILE

Advertising