VEGA VEGAFLEX 86 4 … 20 mA_HART two-wire Rod and cable probe With SIL qualification User Manual

Page 89

Advertising
background image

89

12 Supplement

VEGAFLEX 86 • 4 … 20 mA/HART two-wire

44234-EN-130823

Vessel pressure relating to the flange

nominal stage

see supplementary instructions manual "Flanges ac-

cording to DIN-EN-ASME-JIS"

Process pressure

-1 … +400 bar/-100 … +40000 kPa

(-14.5 … +5800 psig), depending on the process fitting

Process temperature

-196 … +280 °C (-321 … +536 °F)

1

2

0°C

(32°F)

-40°C

(-104°F)

65°C

(149°F)

80°C

(176°F)

280°C

(536°F)

250°C

(482°F)

190°C

(374°F)

3

4

-196°C

(-321°F)

-80°C

(-112°F)

55°C

(131°F)

Fig. 53: Ambient temperature - process temperature (version -196 … +280 °C/-321 … +536 °F)
1 Ambient temperature

2 Process temperature (depending on the seal material)

3 Maximum permissible temperature - standard

4 Limited temperature range - plastic housing and stainless steel housing, electropolished

Process temperature

-196 … +450 °C (-321 … +842 °F)
The measurement error from the process conditions is in

the specified pressure and temperature range of below

1 %.

1

2

0°C

(32°F)

-40°C

(-104°F)

80°C

(176°F)

450°C

(842°F)

220°C

(428°F)

3

4

-196°C

(-384.8°F)

-20°C

(-68°F)

-110°C

(-230°F)

35°C

(95°F)

Fig. 54: Ambient temperature - process temperature (version -196 … +450 °C/-321 … +842 °F)
1 Ambient temperature

2 Process temperature (depending on the seal material)

3 Maximum permissible temperature - standard

4 Limited temperature range - plastic housing and stainless steel housing, electropolished