VEGA VEGAFLEX 86 4 … 20 mA_HART two-wire Rod and cable probe With SIL qualification User Manual
Page 87
87
12 Supplement
VEGAFLEX 86 • 4 … 20 mA/HART two-wire
44234-EN-130823
L
0
-15 mm
(-0.591
"
)
2 mm
(0.079
")
-2 mm
(-0.079
")
25 mm
(0.984
"
)
0,2 m
(7.874
")
0,15 m
(5.906
"
)
0,08 m
(3.15
")
0,1 m
(3.937
")
1
1
Fig. 51: Deviation VEGAFLEX 86 in cable version 2 mm (0.079 in), in oil
1 Dead band - no measurement possible in this area
L Probe length
L
0
-15 mm
(-0.591")
2 mm
(0.079")
-2 mm
(-0.079")
25 mm
(0.984")
0,2 m
(7.874")
0,15 m
(5.906")
0,15 m
(5.906")
0,1 m
(3.937")
1
1
Fig. 52: Deviation VEGAFLEX 86 in cable version 4 mm (0.157 in), in oil
1 Dead band - no measurement possible in this area
L Probe length
Repeatability
≤ ±1 mm
Specification for safety accuracy (SIL)
Siehe Safety Manual
Variables influencing measurement accuracy
Specifications for the digital measured value
Temperature drift - Digital output
±3 mm/10 K relating to the max. measuring range or
max. 10 mm (0.394 in)
Additional deviation through electromag-
netic interference acc. to EN 61326
< ±10 mm (< ±0.394 in)