VEGA VEGABAR 81 Modbus and Levelmaster protocol - Operating Instructions User Manual
Page 58
58
10 Supplement
VEGABAR 81 • Modbus and Levelmaster protocol
46293-EN-131107
90 %
100 %
10 %
t
t
T
A
t
t
S
2
1
Fig. 32: Sudden change of the process variable. t
T
: dead time; t
A
: rise time; t
S
: jump response time
1 Process variable
2 Output signal
Dead time
≤ 45 ms
Rise time
≤ 35 ms (10 … 90 %)
Step response time
≤ 80 ms (ti: 0 s, 10 … 90 %)
Damping (63 % of the input variable)
0 … 999 s, adjustable
Reference conditions and actuating variables (according to DIN EN 60770-1)
Reference conditions according to DIN EN 61298-1
Ʋ Temperature
+18 … +30 °C (+64 … +86 °F)
Ʋ Relative humidity
45 … 75 %
Ʋ Air pressure
860 … 1060 mbar/86 … 106 kPa (12.5 … 15.4 psi)
Determination of characteristics
Limit point adjustment according to IEC 61298-2
Characterstic curve
Linear
Reference installation position
upright, diaphragm points downward
Influence of the installation position
depending on the chemical seal version
Deviation (according to IEC 60770)
Turn down (TD) is the relation nominal measuring range/adjusted span.
Accuracy class
Non-linearity, hysteresis and re-
peatability with TD 1 : 1 up to 5 : 1
Non-linearity, hysteresis and re-
peatability with 5 : 1
0.2 %
< 0.2 %
< 0.04 % x TD
Influence of the product or ambient temperature
Thermal change zero signal and output span
Turn down (TD) is the relation nominal measuring range/adjusted span.
Average temperature coefficient,
zero signal
In the compensated tem-
perature range 10 … +70 °C
(+50 … +158 °F)
Outside the compensated tem-
perature range
Turn down 1 : 1
< 0.05 %/10 K
typ. < 0.05 %/10 K