Thermo electron autopilot, Wiring plan, Parameter – VEGA VEGAPULS 63 (≥ 2.0.0 - ≥ 4.0.0) Modbus and Levelmaster protocol User Manual
Page 75: 12 supplement
Advertising
75
12 Supplement
VEGAPULS 63 • Modbus and Levelmaster protocol
41364-EN-130228
Thermo Electron Autopilot
Wiring plan
+
+
power supply
MODBUS
D0
D1
IS GND
USB
1
2
3
13
45
2o
ff
on
( )
()
(-)
(-)
+8
+30 Vdc
to
GND
2
1
Rx -
Rx+
Fig. 50: Connection of VEGAPULS 63 to RTU Thermo Electron Autopilot
1 VEGAPULS 63
2 RTU Thermo Electron Autopilot
3 Voltage supply
Parameter
Parameter
Value
Baud Rate
9600
Floating Point Format Code
0
RTU Data Type
IEE Fit 2R
Input Register Base Number
0
The basic number of the input registers is always added to the input register address of VEGAPULS
63.
Address 1300 must hence be entered as register address for 1300 for RTU Thermo Electron Auto-
pilot.