VEGA VEGASWING 66 - two-wire With SIL qualification User Manual

Page 38

Advertising
background image

38

9 Supplement

VEGASWING 66 • - two-wire

44952-EN-130805

450 °C

(842 °F)

-196 °C

(-321 °F)

-40 °C

(-40 °F)

0 °C

(32 °F)

50 °C

(122 °F)

80 °C

(176 °F)

-20 °C

(-4 °F)

250 °C

(482 °F)

-110 °C

(-166 °F)

1

2

Fig. 52: Ambient temperature - Process temperature
1 Process temperature in °C (°F)

2 Ambient temperature in °C (°F)

Viscosity - dynamic

0.1 … 1000 mPa s (requirement: with density 1)

Flow velocity

max. 6 m/s (with a viscosity of 1000 mPa s)

Density

0.7 … 2.5 g/cm³ (0.025 … 0.09 lbs/in³); 0.47 … 2.5 g/

cm³ (0.0163 … 0.09 lbs/in³) by switching over

Vibration resistance

Ʋ Instrument housing

1 g at 5 … 200 Hz according to EN 60068-2-6 (vibration

with resonance)

Ʋ Sensor

1 g with 5 … 200 Hz according EN 60068-2-6 (vibration

at resonance) with sensor length 50 cm (19.69 in)

Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Cable entry/plug

4)

Ʋ Single chamber housing

– 1 x cable entry M20 x 1.5 (use seal according to the

cable diameter), 1 x blind plug M20 x 1.5

or:

– 1 x closing cap ½ NPT, 1 x blind plug ½ NPT

or:

– 1␣x plug (depending on the version), 1␣x blind stopper

M20␣x␣1.5

Spring-loaded terminals

for wire cross-section up to 1.5 mm² (AWG 16)

Electromechanical data - version IP 66/IP 68 (1 bar)
Cable entry

Ʋ Single chamber housing

– 1 x IP 68 cable gland M20 x 1.5; 1 x blind plug

M20 x 1.5

or:

– 1 x closing cap ½ NPT, 1 x blind plug ½ NPT

Connection cable

Ʋ Wire cross-section

> 0.5 mm² (AWG 20)

Ʋ Wire resistance

< 0.036 Ω/m (0.011 Ω/ft)

4)

Depending on the version M12 x 1, according to ISO 4400, Harting, 7/8" FF.

Advertising