2 principle of operation, 3 adjustment – VEGA VEGASWING 66 - two-wire With SIL qualification User Manual

Page 9

Advertising
background image

9

3 Product description

VEGASWING 66 • - two-wire

44952-EN-130805

3.2 Principle of operation

VEGASWING 66 is a point level sensor with tuning fork for point level

detection.
It is designed for industrial use in all areas of process technology and

can be used in liquids. It is particularly suitable for applications with

high temperatures up to 450 °C (842 °F) and high process pressure

up to 160 bar (2320 psig).
Typical applications are overfill and dry run protection. The small

tuning fork allows use in pipelines. Thanks to its simple and rugged

measuring system, VEGASWING 66 is virtually unaffected by the

chemical and physical properties of the liquid.
It functions even under difficult conditions such as turbulence, foam

generation, buildup, strong external vibration or changing products.
Function monitoring

The electronics module of VEGASWING 66 continuously monitors via

frequency evaluation the following criteria:

Strong corrosion or damage on the tuning fork

Loss of vibration

Line break to the vibrating drive

If one of these faults is detected, the electronics signals it via a

defined current to the signal conditioning instrument. The connection

cable to the sensor is also monitored for line break and short-circuit.

The tuning fork vibrates at its mechanical resonance frequency of

approx. 1400 Hz. When the tuning fork is submerged in the product,

the frequency changes. This change is detected by the integrated

electronics module, passed on to the processing system as a current

value and converted there into a switching command.

Depending on your requirements, VEGASWING 66 with two-wire

electronics can be connected to different signal conditioning instru-

ments. Compatible signal conditioning instruments are listed in

chapter "Technical data".
The data for power supply are specified in chapter "Technical data".

3.3 Adjustment

With the factory setting, products with a density > 0.07 g/cm³

(0.025 lbs/in³) can be detected. The instrument can be adapted to

products with lower density.
On the electronics module you will find the following display and

adjustment elements:

Signal lamp for indication of the operating status (green)

Signal lamp for indication of the switching status (yellow)

Control lamp for fault indication (red)

DIL switch for sensitivity adjustment

Mode switch for selecting the switching behaviour (min./max.)

Test key

Application area

Functional principle

Voltage supply

Advertising