VEGA VEGAFLEX 82 4 … 20 mA_HART four-wire User Manual

Page 68

Advertising
background image

68

11 Supplement

VEGAFLEX 82 • 4 … 20 mA/HART - four-wire

41830-EN-130314

Ʋ Cable: ø 6 mm (0.236 in)

20 Nm (14.75 lbf ft)

Ʋ Cable: ø 11 mm (0.433 in) - PA coated 20 Nm (14.75 lbf ft)

Ʋ Rod: ø 16 mm (0.63 in)

20 Nm (14.75 lbf ft)

Torque for NPT cable glands and Conduit tubes

Ʋ Plastic housing

max. 10 Nm (7.376 lbf ft)

Ʋ Aluminium/Stainless steel housing

max. 50 Nm (36.88 lbf ft)

Input variable
Measured variable

Level of solids

Min. dielectric constant of the medium

ε

r

≥ 1.5

4

5

3

1

2

4

5

3

1

2

Fig. 38: Measuring ranges - VEGAFLEX 82
1 Reference plane

2 Probe length L

3 Measuring range

4 Upper dead band (see diagrams under Accuracy - grey section)

5 Lower dead band (see diagrams under Accuracy - grey section)

Output variable
Output signals

4 … 20 mA/HART - active; 4 … 20 mA/HART - passive

Terminal voltage passive

9 … 30 V DC

Shortcircuit protection

Available

Potential separation

Available

Signal resolution

0.3 µA

Failure signal current output (adjustable) Last valid measured value, ≥ 21.0 mA, ≤ 3.6 mA
Max. output current

22 mA