VEGA VEGAPULS 62 (≥ 2.0.0 - ≥ 4.0.0) Modbus and Levelmaster protocol User Manual

Page 21

Advertising
background image

21

4 Mounting

VEGAPULS 62 • Modbus and Levelmaster protocol

41362-EN-121011

Small, inclined sheet metal baffles above the installations scatter the

radar signals and prevent direct interfering reflections.

Fig. 18: Cover smooth profiles with deflectors

If there are agitators in the vessel, a false signal suppression should

be carried out with the agitators in motion. This ensures that the

interfering reflections from the agitators are saved with the blades in

different positions.

Fig. 19: Agitators

Through the action of filling, stirring and other processes in the vessel,

compact foams that considerably damp the emitted signals may form

on the product surface.
If foams are causing measurement errors, the biggest possible radar

antennas, the electronics with increased sensitivity or low frequency

radar sensors (C band) should be used.
As an alternative, sensors with guided microwave can be used. These

are unaffected by foam generation and are best suited for such ap-

plications.

When using a surge pipe in a vessel, influences from vessel installa-

tions and turbulences can be excluded. Under these prerequisites,

the measurement of products with low dielectric values (ε

r

value

≥ 1.6) is possible. In very adhesive products, measurement in a surge

pipe is not recommended.

Agitators

Foam generation

Measurement in a surge

pipe

Advertising