EXAMPLES:
Example 1:
Set Egress Button in Momentary contact 5 seconds with delay & warning beep

90

2

5

#

(a) (b) (c) (d)

(a) Egress function programming, (b) Momentary contact with warning, (c) Delay time of 5 seconds

to release door, (d) Entry confirmation

Example 2: Set Egress Button in Holding contact of 10 seconds with warning beep

90

5

10

#

(a) (b) (c) (d)

(a) Egress function programming, (b) Holding contact mode with warning, (c) Holding time of 10

seconds to release door, (d) Entry confirmation

Example 3: Set Egress Button in Momentary contact without delay (This is the default setting)

90

1

0

#

(a) (b) (c) (d)
(a) Egress function programming, (b) Momentary contact without delay, (c) Release door instantly,

(d) Entry confirmation

DOOR OPENING ALARM & TIMER (Location 91)

ALARM & TIMING OF DOOR OPENING

0

--- No Alarm – (Default)

The Alarm Output is disabled

1

999

--- Alarm Timer

The Door Open Alarm operates the Alarm Output (Terminal 20) only. It is mainly prepared to trigger

an optional alarm system. Put any Timing Figure of 1 to 999 into the box to enable the function

of the Door Opening Alarm. The figure is the time in second of the alarm duration, which starts to

count after the door is opened and it resets automatically when the time reaches.
The alarm can be stopped with the User Codes/Cards or the Super User PIN for Output 1 at any

time before the end of the alarm time.

NOTE: The Door Opening Alarm is designed to protect the emergency exit door from use by the un-

authorized person. The alarm occurs when the door is opened or forced to open. However, Alarm will

not happen if the door is opened with a valid User Code or Card.
The Manner of The Door Opening Alarm:
a) The door is forced to open without using PIN/Card – Alarm
b) The door is opened with Egress Button – Alarm
c) The door is opened with PIN/Card – No Alarm

To prevent confusion of the alarm outputs. It is suggested to disable the "Door Forced Open Warning"

at Location 80 while "Door Opening Alarm" function is enabled. If both functions at Location 80 and

Location 91 are enabled and are set with different timings, the system will combine them and will take

the longer one for alarm time.

CLOSE THE PROGRAMMING MODE (

* *

)

Always close programming mode with

* *

to set system back to normal Operation after

programming.

VALIDATION

**

------------------------------- System is back to normal operation mode

ALARM TIME

VALIDATION

LOCATION

0

or

1

-

999

91

#

28