Velleman HAA2866 User Manual

Page 39

Advertising
background image

38

2) BASIC WIRINGS OF A STAND ALONE DOOR LOCK WITH INHIBIT AUTHORIZATION CODE

Use output 3 as authorization control. The owner may key in the user code 3 to stop the operation

of the electric lock in the night time or after office hour to prevent unauthorized access.
Set output 3 in Start / Stop mode (Programming Location 53 Output Mode =0) for ON-OFF

control.
Simply connect the "output 1 inhibit" (O/P 1 INHIB) terminal with output 3 as like the wiring diagram

shown. User code 1 is invalid while the "O/P 1 INHIB" terminal is shunted to ground with user code 3.

NOTE:
1) The Inhibit Authorization Control in this example is made up with hardware connection of Output

3 to the “Output 1 Inhibit” terminal. It gives inhibit function to all User PINs and Cards and the Egress

Button for Output 1 with the User PIN 3.
2) A software Inhibit function is also available in the keypad. It is made up with the
.The Inhibit function in this way gives to all User PINs and Cards for
Output 1 only but not to the Egress Button. Please see Location 02 for the details.

SUPER USER PIN

#

9

DK-2862