Velleman HAA2866 User Manual

Page 37

Advertising
background image

36

8 0

Door Forced Open
Warning & Time

FUNCTION MODE / TIME:

0---OFF

1-999 Seconds

80

FUNCTION / TIME

#

Mode = 0,

Door Forced

Open

Warning OFF

8 1

Propped-up
Warning & Time

81

FUNCTION / TIME

#

Mode = 0,

Propped-up

Warning OFF

9 0

Egress Delay
Warning & Alarm

CODE 1 - FUNCTION MODE:

1---Momentary, No warning

2---Momentary, with warning

3---Momentary, with warning +

Alarm

4---Hold Contact, No warning

5---Hold Contact, with warning

6---Hold Contact, with warning +

Alarm

CODE 2 - DELAY TIME:

0---No Delay

1-99 Seconds

90

CODE 1

CODE 2

#

Mode = 1
Momentary,
No warning
TIME = 0
No Delay

9 1

Door Opening
Alarm & TIMER

ALARM TIME:

0---No Alarm

1-999 Seconds

91

ALARM TIME

#

Time = 0,
No Alarm

9 4

Operation Mode &
Wiegand Output

MODES OF WIEGAND OUTPUT
0---Stand Alone Keypad-Valid
Codes & Cards Only
1---Reader-All Codes & Cards
2---Master Keypad-Valid Codes &
Cards only
3---Slave Keypad-Valid Codes &
Cards only

94

WIEGAND O/P MODE

#

Mode =
0 Keypad
Mode

SYSTEM

CODES

FUNCTION

CODE ENTRY

RESULTS

0 0 0 0

Factory Set Master Code

for User to set system in

programming Mode at the

first time.

THIS IS NOT A

PERMANENT SYSTEM

CODE & IT IS CHANGED

IF A NEW MASTER CODE

IS PROGRAMMED.

0000 * *

OR
NEW MASTER CODE

* *

System in Programming Mode

9 9 9 9

REFRESH CODE -- Refresh

the system and set all its

function back to default

values.

9999 #

All programmed data are cleared
and back to the default values
except the Master Code

8 0 8 0

DAP CODE-- Direct access

to programming mode.

Valid only in the power-up

delay period

8080 #

System in Programming Mode

0 9 9 9

USER PINs / Codes / Cards

whole group clearance

Code - Key in the Code

to clear all the users in the

Location

LOCATIONS:

10--- User Group 1

20--- User Group 2

30--- User Group 3

40--- Vistor Group

41--- Duress Group 1

42--- Duress Group 2

43--- Duress Group 3

LOCATION NO.

0999 #

W h o l e g r o u p o f u s e r s i n t h e
selected location are cleared

* *

Exit Programming Code

**

The system back to normal opration
after programming

Advertising