CONNECTION TERMINALS

1 - 2 : 12V DC (Power Input Terminal)

Connect to 12V DC power supply. The (-) supply and the (-) GND are the common grounding points

of the system. The system accepts full input voltage range with no jumper selection.

3 - 4 - 5 : OUTPUT 1 (Output Relay 1)

5 Amp relay dry contact controlled by the Group 1 User PINs or Cards for Output 1, recommended for

door strike. Terminal 3 is Normally Closed (N.C.), terminal 5 is Normally Open (N.O.) and terminal 4 is

the common point of the two contacts. Use N.C. output for Fail-safe locking device; and N.O. output

for Fail-secure locking device. The relay is programmable for Start/Stop (toggle) mode or Momentary

timing mode. See programming Location 51 for the details.

6 - 7 : DOOR BELL (Output Relay Contact for Door Bell)

It is a Normally Open (N.O.) relay dry contact with maximum rating of 24VDC/1Amp. It is prepared as

a triggering contact of a low voltage door chime. The contact point keeps close as long as the bell

button on the keypad is pressed.

8 : EG IN ( Egress Input)

A Normally Open (N.O.) input terminal referring to (-) ground. With the help of connecting a normally

opened button to activate Output 1 for door opening in the same manner of using the Group 1 User

PINs or Cards.

Egress button is usually put inside the house near the door. More than one egress buttons can be

connected in parallel to this terminal. Leave this terminal open if not used.

See Programming Locations 90 and 91 for more information about the Egress Button with other

features.

9 - 10 - 11 : OUTPUT 2 (Output Relay 2)

1 Amp relay dry contact controlled by the Group 2 User PINs or Cards for Output 2, it is an auxiliary

output ideally for controlling security system or automatic operator. Terminal 9 is Normally Closed

(N.C.), terminal 11 is Normally Open (N.O.) and terminal 10 is the common point of the two

contacts. The relay is programmable for Start/Stop (toggle) mode or Momentary timing mode. See

programming Location 52 for the details.