Distributor Pipe Control - Farm/Commercial
5. Assemble intermediate guide assemblies by attaching the inner mount pipe control bracket
(DPC0005) to the outer pipe guide bracket using two (2) 3/8" x 3/4" bolts (S-7105), two (2)
3/8" flat washers (S-248) and two (2) 3/8" standard flange nuts (S-10028). Use one 3/8" x 3/4" bolt
(S-7105) and one 3/8" flat washer (S-248) to secure the inner mount pipe control bracket (DPC0005)
to the pipe control bracket brace (DPC0021). Secure the bottom of the pipe control bracket brace
(DPC0021) to the middle slot on the outer pipe guide bracket (DPC0018) with one 3/8" x 3/4"
bolt (S-7105), one 3/8" flat washer (S-248) and one 3/8" standard flange nut (S-10028).
Figure 4 Pipe Control Guide Brackets (This is the same assembly for both
intermediate and control lever assemblies.)