SSA (Sequential switching function A): Allows you to sequentially switch between different boost settings. This switch logic could be
applied in a situation where you want to have a different boost level in each gear.

Earthing the green wire with a switch will scroll up a single set point.

Earthing the green wire again will switch up another single set point.

The maximum number of set points that can be switch up to is determined by nSP in the setup menu.

Once the maximum set point is reached through switching further switching not increase the set point any higher.

Earthing orange wire with a switch will reset and return to SP1.































SSB (Sequential switching function B): Sequential Switching Function B allows you to sequentially switch up and down between
different boost settings using external switches. This switch logic could be applied in a situation where you want to have a different
boost levels in each gear.

Earthing the green wire with a switch will switch up a single set point.

Earthing the green wire again will switch up another single set point.

The maximum number of set points that can be switch up to is determined by nSP in the setup menu.

Once the maximum set point is reached through switching (note: will only switch up to SP6).

Earthing orange with a switch will wire switch down a single set point.

Earthing the orange wire again will down another set point. (note: will only switch down to SP1).






















Boost Curve

SP1

SP2

SP3

SP4

Ground Orange

Wire- Reset to SP1

Ground Green W ire

- trigger up SP

BOOST

SP5

SP6

TIME

Example Boost

SP1

Ground Green

Wire- trigger up SP

Ground Orange

Wire- trigger down

SP

SP2

SP3

SP4

SP5

BOOST

SP4

SP5

SP6

SP2

SP1

SP3

TIME