EXAMPLE 2: BOOST SPIKING BETWEEN BOOST LEVEL SWITCHING

Earthing the green wire will scroll up through set points starting at SP1 up to SP6 one at a time.

Earthing the orange wire will reset and return to SP1 and dS1 (launch time delay).

To create a spike in boost during the time delay you must set the gate pressure for the relevant boost level higher than the
boost level achieved with the set point. For example if you know that a SP2 value of 40 gives you a boost pressure of 14 psi
you can spike your boost pressure to say 17 psi by setting GP2 = 17 psi.

You must also set the time interval dS during which you want your boost spike.

If your time interval (dS) expires before your gate pressure spike is reached the boost level will go to the SP boost level.

If your gate pressure is reached before the time interval dS expires then the time interval will be cut short and the boost level
will return to the boost level for the next set point.































EXAMPLE 3: COMBINATION OF BOOST SPIKING & BOOST DIPPING BETWEEN BOOST LEVEL SWITCHING

-

A combination of spikes and dips as shown below can be achieved through entering zero gate pressure where you want a dips and
a gate pressure (the max of the spike) where you want a boost spike.































Example Boost Curve - Boost Spiking

Orange - Reset

Green – Trigger to

Launch or up SP

Time

SP1

GP1

BOOST

SP1

SP2

SP3

SP4

SP5

SP6

dS1

dS2

dS3

dS4

dS5

dS6

GP2

GP3

GP4

GP5

GP6

Combination Curve

Orange - Reset

Green – Trigger to

Launch or up SP

Time

SP1

GP1

BOOST

SP1

SP2

SP3

SP4

SP5

SP6

dS1

dS2

dS3

dS4

dS5

dS6

GP2

GP3

GP4

GP5

GP6

Advertising