Internal wastegates with 2 ports, Twin solenoid, twin parallel turbocharger hook up – Turbosmart BOOST CONTROLLERS – ELECTRONIC - e-Boost2 (2005-current) – Complete User Manual User Manual

Page 7

Advertising
background image

www.TURBOSMARTONLINE.com

7

Internal wastegates with 2 ports

Port (1): vents pressure from the solenoid.


Port (2): connect to one of the ports of the actuator


Port (3): to pressure only source


Block off unused port on the actuator with suitable blank

Single solenoid, twin parallel turbocharger hook up

(For straight configuration twin parallel turbocharger engines E.g. RB26DETT)

The e-Boost2 is capable of controlling twin internal wastegate turbochargers with a single solenoid.

This method is used when the turbochargers are mounted close to each other allowing the solenoid to be mounted close to both
actuators

Each solenoid port is connected as follows:

Port (1): vents pressure from the solenoid. Connect this hose to the intake side of the turbo, between the air cleaner and the inlet of the
turbocharger. Otherwise connect a short piece of the silicon hose and face the vent downwards to stop water or debris entering the
solenoid.

Port (2): to tee piece that feeds both actuators

Port (3): to pressure only source

Twin solenoid, twin parallel turbocharger hook up

(For V configuration twin parallel turbocharger engines E.g. V6, V8 etc)

The e-Boost2 is capable of controlling two solenoids for twin parallel turbocharger setups.

This method is used when there is a great distance between the wastegates. This allows the solenoids to be mounted close to the
wastegates to minimise the length of hose used and to maximise response

You will need a second solenoid for this method (TS-0301-3003)

Connect the grey wire from the e-Boost wiring loom to one of the wire from each solenoid.


Connect the brown wire from the e-Boost wiring loom to the remaining wire from each solenoid.


Each solenoid port is connected as follows:

Block off with
suitable blank

Turbochargers

Port 1 of solenoid
Vent to atmosphere
or air cleaner

Port 3 of solenoid to
pressure only source

Tee Piece

Actuator

Actuator

Port 2 of solenoid to
tee piece

Pressure only
source to port 3
of solenoid

Port 1 of solenoid vent
to atmosphere

Port 2 of solenoid
to actuator

Block off unused
port