4 clock characteristics, 1 calibrated internal oscillator accuracy, 2 external clock drive – Rainbow Electronics ATtiny43U User Manual

Page 157: Table, Calibration in, Frequencies as specified in, Table 20

Advertising
background image

157

8048B–AVR–03/09

20.4

Clock Characteristics

20.4.1

Calibrated Internal Oscillator Accuracy

It is possible to manually calibrate the internal oscillator to be more accurate than default factory calibration. Please note
that the oscillator frequency depends on temperature and voltage.

Notes:

1. Accuracy of oscillator frequency at calibration point (fixed temperature and fixed voltage).

20.4.2

External Clock Drive

Figure 20-2. External Clock Drive Waveforms

Table 20-2.

Calibration Accuracy of Internal Oscillator

Calibration
Method

Target Frequency

V

CC

Temperature

Accuracy at given Voltage

& Temperature

(1)

Factory
Calibration

8.0 MHz

3V

25

°

C

±10%

User
Calibration

Fixed frequency within:

7.3 - 8.1 MHz

Fixed voltage within:

1.8V - 5.5V

Fixed temperature within:

-40

°

C - 85

°

C

±1%

Table 20-3.

External Clock Drive Characteristics

Symbol

Parameter

V

CC

= 1.8 - 5.5V

V

CC

= 2.7 - 5.5V

Units

Min.

Max.

Min.

Max.

1/t

CLCL

Clock Frequency

0

4

0

8

MHz

t

CLCL

Clock Period

250

125

ns

t

CHCX

High Time

100

50

ns

t

CLCX

Low Time

100

50

ns

t

CLCH

Rise Time

2.0

1.6

μ

s

t

CHCL

Fall Time

2.0

1.6

μ

s

Δ

t

CLCL

Period change from clock cycle to next

2

2

%

V

IL1

V

IH1

Advertising