Attiny43u – Rainbow Electronics ATtiny43U User Manual

Page 170

Advertising
background image

170

8048B–AVR–03/09

ATtiny43U

ROR

Rd

Rotate Right Through Carry

Rd(7)

C,Rd(n)

Rd(n+1),C

Rd(0)

Z,C,N,V

1

ASR

Rd

Arithmetic Shift Right

Rd(n)

Rd(n+1), n=0..6

Z,C,N,V

1

SWAP

Rd

Swap Nibbles

Rd(3..0)

Rd(7..4),Rd(7..4)

Rd(3..0)

None

1

BSET

s

Flag Set

SREG(s)

1

SREG(s)

1

BCLR

s

Flag Clear

SREG(s)

0

SREG(s)

1

BST

Rr, b

Bit Store from Register to T

T

Rr(b)

T

1

BLD

Rd, b

Bit load from T to Register

Rd(b)

T

None

1

SEC

Set Carry

C

1

C

1

CLC

Clear Carry

C

0

C

1

SEN

Set Negative Flag

N

1

N

1

CLN

Clear Negative Flag

N

0

N

1

SEZ

Set Zero Flag

Z

1

Z

1

CLZ

Clear Zero Flag

Z

0

Z

1

SEI

Global Interrupt Enable

I

1

I

1

CLI

Global Interrupt Disable

I

0

I

1

SES

Set Signed Test Flag

S

1

S

1

CLS

Clear Signed Test Flag

S

0

S

1

SEV

Set Twos Complement Overflow.

V

1

V

1

CLV

Clear Twos Complement Overflow

V

0

V

1

SET

Set T in SREG

T

1

T

1

CLT

Clear T in SREG

T

0

T

1

SEH

Set Half Carry Flag in SREG

H

1

H

1

CLH

Clear Half Carry Flag in SREG

H

0

H

1

DATA TRANSFER INSTRUCTIONS

MOV

Rd, Rr

Move Between Registers

Rd

Rr

None

1

MOVW

Rd, Rr

Copy Register Word

Rd+1:Rd

Rr+1:Rr

None

1

LDI

Rd, K

Load Immediate

Rd

K

None

1

LD

Rd, X

Load Indirect

Rd

(X)

None

2

LD

Rd, X+

Load Indirect and Post-Inc.

Rd

(X), X

X + 1

None

2

LD

Rd, - X

Load Indirect and Pre-Dec.

X

X - 1, Rd

(X)

None

2

LD

Rd, Y

Load Indirect

Rd

(Y)

None

2

LD

Rd, Y+

Load Indirect and Post-Inc.

Rd

(Y), Y

Y + 1

None

2

LD

Rd, - Y

Load Indirect and Pre-Dec.

Y

Y - 1, Rd

(Y)

None

2

LDD

Rd,Y+q

Load Indirect with Displacement

Rd

(Y + q)

None

2

LD

Rd, Z

Load Indirect

Rd

(Z)

None

2

LD

Rd, Z+

Load Indirect and Post-Inc.

Rd

(Z), Z

Z+1

None

2

LD

Rd, -Z

Load Indirect and Pre-Dec.

Z

Z - 1, Rd

(Z)

None

2

LDD

Rd, Z+q

Load Indirect with Displacement

Rd

(Z + q)

None

2

LDS

Rd, k

Load Direct from SRAM

Rd

(k)

None

2

ST

X, Rr

Store Indirect

(X)

Rr

None

2

ST

X+, Rr

Store Indirect and Post-Inc.

(X)

Rr, X

X + 1

None

2

ST

- X, Rr

Store Indirect and Pre-Dec.

X

X - 1, (X)

Rr

None

2

ST

Y, Rr

Store Indirect

(Y)

Rr

None

2

ST

Y+, Rr

Store Indirect and Post-Inc.

(Y)

Rr, Y

Y + 1

None

2

ST

- Y, Rr

Store Indirect and Pre-Dec.

Y

Y - 1, (Y)

Rr

None

2

STD

Y+q,Rr

Store Indirect with Displacement

(Y + q)

Rr

None

2

ST

Z, Rr

Store Indirect

(Z)

Rr

None

2

ST

Z+, Rr

Store Indirect and Post-Inc.

(Z)

Rr, Z

Z + 1

None

2

ST

-Z, Rr

Store Indirect and Pre-Dec.

Z

Z - 1, (Z)

Rr

None

2

STD

Z+q,Rr

Store Indirect with Displacement

(Z + q)

Rr

None

2

STS

k, Rr

Store Direct to SRAM

(k)

Rr

None

2

LPM

Load Program Memory

R0

(Z)

None

3

LPM

Rd, Z

Load Program Memory

Rd

(Z)

None

3

LPM

Rd, Z+

Load Program Memory and Post-Inc

Rd

(Z), Z

Z+1

None

3

SPM

Store Program Memory

(z)

R1:R0

None

IN

Rd, P

In Port

Rd

P

None

1

OUT

P, Rr

Out Port

P

Rr

None

1

PUSH

Rr

Push Register on Stack

STACK

Rr

None

2

POP

Rd

Pop Register from Stack

Rd

STACK

None

2

MCU CONTROL INSTRUCTIONS

NOP

No Operation

None

1

SLEEP

Sleep

(see specific descr. for Sleep function)

None

1

WDR

Watchdog Reset

(see specific descr. for WDR/Timer)

None

1

BREAK

Break

For On-chip Debug Only

None

N/A