14

AT77C105A [Preliminary]

5419A–BIOM–01/05

Status Register

Register Name: Status (8 bits)

Access Type: Read Only

Function: State of AT77C105A

CLICK: Click detection

0: default

1: click detected

MOV: Movement detection

0: default

1: X or Y movement detected

TRANSIT: Not used, for testing only

SLICE: Not used, for testing only

READERR: Read error detection

0: default, no error

1: read error detected

Note:

To clear the interrupts, the status register is initialized after each reading from the host.

b7

b6

b5

b4

b3

b2

b1

b0

CLICK

MOV

TRANSIT

SLICE

READERR

0

0

0

0

0

0

0

0