Switching performances – Rainbow Electronics AT77C105A User Manual

Page 8

Advertising
background image

8

AT77C105A [Preliminary]

5419A–BIOM–01/05

Switching Performances

The following characteristics are applicable to the operating temperature -40

°C ≤ T ≤ +85°C.

Typical conditions are: nominal value; T

amb

= 25

°C; F

SCK

= 12 MHz; duty cycle = 50%; C

LOAD

120 pF in digital output unless

specified otherwise.

Note:

1. T

SCK

= 1/F

CTRL

(clock period)

Note:

All power supplies = +3.3V

Note:

All power supplies = +2.5V

Table 12. Timings

Parameter

Symbol

Test Level

Min

Typ

Max

Unit

Clock frequency acquisition
mode

F

ACQ

IV

8

16

MHz

Clock frequency navigation
mode and chip control

F

CTRL

I

-

0.2

MHz

Duty cycle (clock SCK)

DC

IV

20

50

80

%

Reset setup time

T

RSTSU

I

½ T

SCK

(1)

ns

Slave select setup time

T

SSSU

I

½ T

SCK

(1)

ns

Slave select hold time

T

SSHD

I

½ T

SCK

(1)

ns

Table 13. 3.3V ±10% Power Supply

Parameter

Symbol

Test Level

Min

Typ

Max

Unit

Data in setup time

T

SU

IV

3

ns

Data in hold time

T

H

IV

1

ns

Data out valid

T

V

I

30

ns

Data out disable time from SS
high

T

DIS

IV

3.8

ns

IRQ hold time

T

IRQ

IV

3

µs

Table 14. 2.5V ±5% Power Supply

Parameter

Symbol

Test Level

Min

Typ

Max

Unit

Data in setup time

T

SU

IV

3

ns

Data in hold time

T

H

IV

1

ns

Data out valid

T

V

I

30

ns

Data out disable time from SS
high

T

DIS

IV

3.8

ns

IRQ hold time

T

IRQ

IV

3

µs

Advertising