Clickctrl register – Rainbow Electronics AT77C105A User Manual

Page 18

Advertising
background image

18

AT77C105A [Preliminary]

5419A–BIOM–01/05

Sets the minimum analog value detected as a high level (‘1’) and the maximum analog
value detected as a low level (‘0’). See Note 3 on page 18.

Notes:

1. Navfreq and Navv registers should not be changed once the navigation mode is

selected. Finger sensitivity refers to the minimum level of information required from a
finger. The sensitivity is linked to the integration time; a longer integration time
enables better sensitivity but does not tolerate fast movement.

2. The navigation frequency is the frequency needed for the reading of one new naviga-

tion frame.

3. The Clickv register should not be changed once the click mode is selected.

Clickctrl Register

Register Name: Clickctrl (7 bits)

Access Type: Read/Write

Function: Click control

CLICKFREQ: Click pixels reading frequency

00: 180 Hz

01: 90 Hz (default value)

10: 60 Hz

11: 45 Hz

Faster frequency enables faster finger click detection. Lower frequency enables higher
sensitivity.

CLICKDET: Threshold for selecting the black/white color of a slice

00: more than 7 black/white pixels and less than 5 white/black pixels

01: more than 8 black/white pixels and less than 4 white/black pixels

10: more than 9 black/white pixels and less than 3 white/black pixels

11: more than 10 black/white pixels and less than 2 white/black pixels

CLICKCPT: Click detection counter (maximum number of slices read between two
transitions)

000: 5

001: 7

010: 10

011: 12

100: 16

101: 20

110: 25

111: 31

b6

b5

b4

b3

b2

b1

b0

CLICKFREQ

(MSB)

CLICKFREQ

(LSB)

CLICKDET

(MSB)

CLICKDET

(LSB)

CLICKCPT

(MSB)

CLICKCPT

CLICKCPT

(LSB)

0

1

0

1

1

0

1

Advertising