Dexter Laundry T-1450 EXPRESS (30-Cycle) User Manual

Page 14

Advertising
background image

14

11. Push the green ENTER button. (The extract time has now been entered.)

Once depressed, the Spin Time LED is out, and the editing of one segment

is complete. The next sequential cycle segment LED lights, unless the

segment edited above was the Final Rinse/Extract segment. If the Final

Rinse/Extract segment is edited, after step eleven, the cycle programming

is complete, and the machine will return to the Programming Mode awaiting

a cycle select (Step 3).

To exit the programming mode, depress the red STOP button when one of
the nine cycle segment LED lights are lit. The programming changes made
prior to the program exit are retained and the cycle is updated.


PROGRAMMING INSTRUCTIONS - ENTERING NEW CYCLES

The T1450 comes from the factory with 29 preset wash cycles programmed into the

washer. Although these cycles are common industry cycles, there may be a need

to add a cycle to meet an exact application. This can easily be done with the

following instructions. Note: It is recommended when cycle(s) are made, the

cycle number and the cycle steps be documented for later reference. Blank

cycle sheets have been provided at the end of the Preset Cycle Information

section.

The instructions for entering a new cycle are the same as the editing a cycle

instructions. Again, only the cycle segments required need to be programmed.

All other segments can be left unprogrammed by ensuring a zero time value is

entered in the cycle time for each unused segment.

WASHER DIAGNOSTIC CYCLE

The diagnostic test cycle provided with every machine aids the user in

verifying correct operation of the washer after scheduled maintenance, and aids

the user in identifying functional problems with the machine.

The diagnostic program, cycle 31, is an individual function test. This program

tests most of the functions of the machine (water valves, drive system, door

lock, etc.). The diagnostic program must be started from the program mode.

The keylock must be in the program position.

Below are two important notes about the diagnostic cycle:

Cycle Terminate - At any time during the diagnostic cycle, depressing and

holding the stop button for a minimum of 3 seconds terminates washer

activities and clears the cycle.

Injection Signals - The injection signals are not tested during the

diagnostic cycle.

Cycle 31 Sequence - Short Individual Function Test

1.

Close the washer door.

2.

Turn the control key to the PROGRAM mode.

3.

Select cycle 31 using the SCROLL UP/SCROLL DOWN buttons.

4.

Push the green START button.

From this point, the operator must observe the functions of the washer to

ensure correct operation. With the top removed, the activation of each

function can be observed. Each step in this test will turn on an output on the

I/O interface assembly. Each time an output is active, the corresponding RED

LED on the I/O interface assembly will light. The outputs are clearly marked.

Advertising