INSTALLATION INSTRUCTIONS

All washers must be installed in accordance with all local, state, and

national building, electrical, plumbing and other codes in effect.

WARNING - THESE INSTALLATION AND SERVICING INSTRUCTIONS ARE FOR

USE BY QUALIFIED PERSONNEL ONLY. TO AVOID INJURY AND ELECTRIC

SHOCK, DO NOT PERFORM ANY SERVICING UNLESS QUALIFIED.

FOUNDATION REQUIREMENTS

This machine is designed for use on or over bare concrete floor - not to be

used above combustible flooring. The washer must be securely bolted to a

substantial concrete floor, or mounted upon a suitable base which is, in turn,

securely bolted to a substantial concrete floor. CARE MUST BE STRESSED WITH

ALL FOUNDATION WORK TO INSURE A STABLE UNIT INSTALLATION, ELIMINATING

POSSIBILITIES OF EXCESSIVE VIBRATION. All installations must be made on sound

concrete floors, 12" or thicker. Anchor bolts must be of a quality grade, and

a minimum of 3/4" diameter. Six (6) mounting bolts must be used.

MOUNTING

A concrete pedestal, or steel mounting base which elevates the machine a

approximately 4" (102 mm) above the floor level is recommended to provide easy

access to the loading door. Actual base height should be determined by

application, considering access to loading door, access to soap dispenser and

height of loading carts. Allow a minimum of 24" of clearance behind the rear

of the machine, to provide access for motor removal. Refer to Figure 1-1 and

1-2 for machine bolt-down dimensions. Refer to Figure 2 for overall washer

dimensions.

If an elevated concrete pedestal is desired, it should be embedded into the

existing floor. Anchor bolts should be 3/4" x 8" 19 mm x 200 mm), grade 8 or

better, headed by a 4 inch (10 cm) square fish plate, and should protrude 2 ½

inches above the finished surface of the pedestal. If anchors are to be

installed in existing concrete we recommend Hilti Adhesive Anchor System with

Hilti HEA 3/4-6 5/8 Adhesive Capsules and Hilti HAS 3/4-9 5/8 Super Rods. (For

more information, contact Hilti Customer Service at 1-800-879-8000). EXPANSION

ANCHORS ARE NOT RECOMMENDED FOR USE IN CONCRETE FLOORS OR PEDESTALS. (See

Figures 1-1 and 1-3.)

PLUMBING

Water supply hoses are furnished with each machine. The threaded connections

on the hoses are 3/4-11 ½ NHT. The small 3/8 ID supply hoses connect to the

lower hot and cold valves which flush the soap box. The larger 5/8 ID supply

hoses connect to the upper hot and cold valves.

Separate hot and cold water lines must be provided, maintaining 30 PSI to 120

PSI water flow pressure.

DRAIN

The drain outlet tube at the rear of the machine is 3 inches in diameter. Any

drain hose used must be lower than the drain valve to assure proper draining

.