1 type – SENA PS400 User Manual

Page 43

Advertising
background image

43

configuration-UART configuration

menu screen.

---------------------------------------------------------------------------

Serial configuration --> port#1 ---> UART

---------------------------------------------------------------------------

Select menu
1. Type : RS232
2. Baud rate : 9600
3. Data bits : 8

4. parity : None
5. Stop Bits : 1
6. Flow control : Hardware
7. DTR behavior : Always High
8. DSR behavior : None

<ESC> Back, <ENTER> Refresh

----->

Figure 4-15. UART configuration menu screen

4.2.1 Type

First of all, the HelloDevice Pro Series and the serial device must agree on the serial communication

type, which is one of RS232, RS422, RS485 echo mode or RS485 non-echo mode. The HelloDevice

Pro Series serial ports are configured for RS232 communication as a factory default, but they can also

be configured for RS422 and RS485 communication. To change the serial communication type, set up

the mode in the Type menu. See Appendix B for serial port connections due to the Type setup.

The HelloDevice Pro Series supports two types of RS485 communication – echo mode and non-echo

mode, which are both two-wire mode. In RS485 echo mode, all data sent to the serial port are

received back from the serial port automatically and compared with the data sent for the data integrity

while there is no action of receiving-back in non-echo mode.

---------------------------------------------------------------------------

Serial configuration --> port#1 ---> UART

---------------------------------------------------------------------------

Select menu
1. Type : RS232
2. Baud rate : 9600

3. Data bits : 8
4. parity : None
5. Stop Bits : 1
6. Flow control : Hardware
7. DTR behavior : Always High

8. DSR behavior : None

<ESC> Back, <ENTER> Refresh

-----> 1
Select serial type
1 = RS232, 2 = RS485 Echo, 3 = RS485 NonEcho, 4 = RS422
----->

Advertising