A.1.6. flow control(fc_ctrl) on/off signal, A.1.8. reset signal – SENA Parani-BCD110-210 User Manual

Page 42

Advertising
background image

42

Step 5. Now BCD1 is waiting for a connection from the last connected Bluetooth device. The last

connected Bluetooth device can connect to BCD1.

Table A-3 Pairing Process with other Bluetooth device by Pairing Signal

BCD1

Status

Pairing Signal

Other Bluetooth Device

Status

1. Reset

Mode0

HIGH

2. Drop pairing signal

Mode3

LOW

3. Inquiry and connect to

BCD1

4. Connected

Slave

HIGH

4. Connected

Master

A.1.6. Flow Control(FC_CTRL) On/Off Signal

If user wants to set the status of hardware flow control option using AT+UARTCONFIG command,
FC_CTRL signal should be connected with UART_CTS signal.

If Hwfc parameter in AT+UARTCONFIG command is set to 1, FC_CTRL signal is set to high and then
hardware flow control is enabled. And if Hwfc parameter in AT+UARTCONFIG command is set to 0,
FC_CTRL signal is set to low and then hardware flow control is disabled.

A.1.7. Bluetooth Status LED(STATUS_LED0, STATUS_LED1) Signal

<STATUS_LED0>

If any Bluetooth device is connected, this signal is set to high during 150msec periodically
after low status during 1 sec.

<STATUS_LED1>

When the connection status is Standby, this signal is set to high.

When the connection status is Pending, this signal is toggled 3 times periodically after low
status during 1 sec.

When the connection status is Connect, this signal is set to low.

A.1.8. Reset Signal

Parani-BCDx10 can be reset from one of following sources:

-

RESETB pin

-

Power on reset

-

UART break character

Advertising