Control valve function and cycles of operation, How to set timer control, User displays – Aqua-Pure CBF150 User Manual

Page 13

Advertising
background image

2-7

Control Valve Function and Cycles of Operation

The AC adapter comes with a 15 foot power cord that is designed for use with the control valve. The AC adapter is for dry location use only. If the power
goes out, only the time of day needs to be reset. All other settings are permanently stored in the non-volatile memory.

The following chart shows the time for the backwash and rapid rinse cycles for the three available programming options.

Regeneration Cycles and Times for Different Programs

Program Number

Length of Cycle Times (Minutes)

BACKWASH (C1)

RAPID RINSE (C4)

P7

6

4

P8

10

6

P9

14

8

Note: Your CBF Series Residential Backwash Filtration System is factory preset to program number P7, changing the setting to P8 or P9 is rarely needed.
But if a change is desired, please refer to “How to Change the Regeneration Program Settings” on page 2-6.

HOW TO SET TIMER CONTROL

SET

HOUR

Regen

Min. Fill

Regen

Hour

Time - Hour

PM

Days To Regen

Power Loss

If the power goes out, current time of day will need to be reset. If the power goes out while the system is
regenerating, the cycle picks up where it was when the power went out.

Error Message

If “E1” “E2” or “E3” appears on the display, contact your Dealer/Installer or our Customer Service Depart-
ment at 1-800-222-7880. These are error codes and will need to be resolved before the control valve will
function. These codes indicate that the control valve did not function properly.

USER DISPLAYS

General Operation

When operating, the system will either display the current time of day or the days remaining until the next regen-
eration. Use

▲ or ▼ to toggle between the two displays. If the remaining days is at 1, the system will regenerate

at the preset time.

An arrow will appear pointing to REGEN when the system calls for regeneration.

Regeneration Mode

When the system is regenerating, untreated water will be used. Therefore, systems are typically set to regenerate
during times of low water usage—such as when the household is asleep.

During regeneration, the arrow will point to REGEN and the display will change to Regeneration Cycle Display,
indicating the time remaining. The system automatically runs through the steps of regeneration; upon comple-
tion, treated water is ready for use.

SET

Regen
Min. Fill
Regen
Time

Time
PM
Days To
Regen

SET

Regen
Min. Fill
Regen
Time

Time
PM
Days To
Regen

Arrow will point to Regen
if a regeneration is
expected “Tonight.”