IMPORTANT: SECTION 1: BEFORE INSTALLATION

Inspecting And Handling Your Filtration System:

Inspect the equipment for shipping damage. If damaged, notify the transportation company and request a damage inspection. Handle the system with care.
Damage can occur if dropped or set on sharp, uneven projections on the fl oor. Do not turn the system upside down.

We Recommend Testing Your Water Prior to Installation:

An analysis of your water should be made prior to the selection of your water conditioning equipment and fi lter media. Enter your water analysis results below
for a permanent record.

IMPORTANT NOTE:

IMPORTANT NOTE:

Hydrogen sulfi de (H

2

S) must be tested for at the well site. For accuracy, the sample must be drawn with the pump RUNNING and the test be completed

within ONE minute after the sample is drawn.

Analysis Of Your Water

Hardness gpg

Tannins (Humic Acid) ppm

Iron (Fe) ppm

Hydrogen Sulfi de (H

2

S) ppm

Manganese (Mn) ppm

Other ppm

pH ppm

Other ppm

There are several different fi lter media which can be used in this system. Each is designed to improve a particular aesthetic problem. None of them should be
used to make non-potable water safe to drink.

Media

Application

Activated Carbon

Chlorine Taste & Odor, Organics, Dechlorination

Activated Carbon for Chloramine

Chloramine Taste & Odor, Organics, Dechlorination

Neutralizer Blend

pH adjustment when pH is appx. 6.0 - 6.5

Filter Sand

Precipitated Iron, Turbidity

Filter-Ag

®

Turbidity Reduction (20 micron)

Birm

®

Iron (Water must be rich in dissolved oxygen)

Calcium Carbonate (Calcite)

pH adjustment

Magnesium Oxide

Increase pH

Multilayer

Turbidity, Sediment & Chlorine Taste and Odor Reduction

Greensand

3

Precipitated iron, Manganese & low Hydrogen Sulfi de

1. CBF series fi lters could be used to neutralize acid water. However, UN Series fi lters are better suited for this purpose.
2. When using Filter-Ag or Filter Sand for the reduction of turbidity, the suspended solids causing the turbidity must have a density less than the material being used as a fi ltering agent.
3. May require use of a solution tank and a change to the controller. Contact Technical Service for more information.

1-1

TABLE OF CONTENTS

SECTION

DESCRIPTION

1

BEFORE INSTALLATION

2

INSTALLATION

3

MAINTENANCE

4

TROUBLESHOOTING

5

SPECIFICATION AND OPERATING DATA

6

COMPONENT PARTS LIST

7

LIMITED WARRANTY

• Professional Installation Required: Installation requires shutting water off to home, cutting home water supply pipe and

using a soldering torch to add piping and fittings. Specialized tools and skills are required.