Problem

Possible Cause

Solution

9)

Media in aerators at the faucets

A)

Unit installed backwards

1)

Ensure that the piping enters to INLET side of bypass
and exits on the OUTLET side. (Refer to red handles
on bypass to check for fl ow direction.)

B)

Distributor is damaged

1)

Remove distributor tube from media tank and in-
spect. Replace as needed

C)

Media was loaded in distributor
tube while loading fi lter unit.

1)

Remove distributor tube from media tank, clean and
reinstall correctly. Cover distributor tube with plug
provided or something appropriate

10)

Water leaking from media tank

A)

Media tank was subjected to a
vacuum condition

1)

Replace media tank and check to see that either a
check valve or back fl ow prevention device is in-
stalled and operating

B)

Media tank is damaged

1)

Contact installing contractor to have evaluated and
replaced

C)

Pin hole in media tank

1)

Contact installing contractor to have evaluated and
replaced

11)

Time of day fl ashes on and off

A)

Power has been off for more
than two hours

1)

Reset the time of day

B)

Transformer was unplugged from
either wall outlet or PC board

1)

Reset the time of day

C)

SET HOUR was pressed

1)

Reset the time of day

12)

Valve stalled in regeneration

A)

Motor not operating

1)

Replace motor

B)

No power at the outlet

1)

Repair outlet or use a working outlet

2)

Check circuit breaker at the main power box

C)

Damaged transformer

1)

Replace transformer

D)

Damaged PC board

1)

Replace PC board

E)

Damaged drive gear or drive cap
assembly

1)

Replace gear or drive cap assembly

F)

Damaged piston retainer

1)

Replace main piston assembly

G)

Damaged main piston

1)

Replace main piston assembly

13)

Valve does not regenerate automatically
when the

and

button is pushed

A) Transformer

unplugged

1)

Connect transformer and the PC board power

B)

No power at outlet

1)

Restore or repair power source

C)

Damaged drive gear or drive cap
assembly

1)

Replace gear or drive cap assembly

D)

Damaged PC board

1)

Replace PC board

14)

Valve does not regenerate automatically,
but does when

and

is depressed

A)

Programming error

1)

Review programming of control valve

B)

Damaged PC Board

1)

Replace PC board

C)

Meter wire not securely
installed into connector

1)

Verify meter wire installed securely into three pin
connector labeled METER